Seitenansicht 0
Installation, Operation
and Maintenance Manual
4-Stage Reverse Osmosis Systems
Model PWRO4
IOM-WQ-PWRO4
Important
Please read the entire manual before proceeding with the
installation and startup. Your failure to follow any attached
instructions or operating parameters may lead to the product’s
failure.
Save manual for future reference.
Table of Contents Pages
Operational Parameters...................................3
Contents of Reverse Osmosis System........................3
Tools Recommended For Installation .........................3
Drill a Hole for the Faucet in a Porcelain Sink ...................3
Punch a Hole for the Faucet in a Stainless Steel Sink.............3
Watts Standard Faucet Installation...........................4
Adapt-A-Valve™ Installation ...............................5
Drain Saddle Installation ..................................5
Drill Hole and Connect
3
8" Black Tube
from Faucet to the Drain Saddle ............................6
Green Tube Connection...................................6
Reverse Osmosis Module Mounting .........................6
Red
1
4" Tube Connection (from faucet) .......................6
Check Air Pressure in the Tank .............................6
Tank Tee Installation......................................6
Blue Tube Connection (from System) .........................7
Final Filter Installation.....................................7
Start Up Instructions .....................................7
6-Month Maintenance ....................................8
Annual Maintenance .....................................8
Membrane Replacement ..................................9
Procedure for Extended Non-Use (More than 2 months) ..........9
Troubleshooting........................................10
Parts List .............................................11
Arsenic Facts..........................................12
Service Record ........................................13
Limited Warranty .......................................16
PWRO4
PURE WATER
System tested and certified by NSF International
against NSF/ANSI Standard 58 for the reduction
of the claims specified on the performance data
sheet.
Note: Do not use with water that is microbiologically unsafe or
of unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
Seitenansicht 0
1 2 3 4 5 6 ... 15 16

Inhaltsverzeichnis

Seite 1 - PURE WATER

Installation, Operation and Maintenance Manual4-Stage Reverse Osmosis SystemsModel PWRO4IOM-WQ-PWRO4ImportantPlease read the entire manual before pro

Seite 2 - Introduction

10PROBLEM CAUSE SOLUTION1. Low/Slow production Low water pressure Assure a minimum of 40psi incoming water pressure. Watts sells a booster pump if hom

Seite 3

11 Parts ListITEM # EDP # DESCRIPTION1 7300068 ADAPT-A-VALVE™2 7100174 STORAGE TANK-3 GAL WHITE3 7300031 ELBOW - 1⁄4" C x 1⁄4" M4 7300060

Seite 4 - Standard Faucet Installation

12 Arsenic FactsArsenic (As) is a naturally occurring contaminant found in many ground waters. Arsenic in water has no color, taste or odor. It must b

Seite 5 - 2" Configuration

13DATE OF PURCHASE DATE OF INSTALL INSTALLED BYDATE 1ST STAGE SEDIMENT (6 MONTHS)2ND STAGE CARBON (6 MONTHS)3RD STAGE CARBON (6 MONTHS)FINAL FILTER

Seite 8 - Annual Maintenance

IOM-WQ-PWRO4 1225 EDP# 2915876 © 2012 WattsUSA: North Andover, MA • Tel. (800) 224-1299 • www.watts.com Canada: Burlington, ON • Tel. (888) 208-8

Seite 9 - Membrane Replacement

2IntroductionThank you for your purchase of a state of the art Watts Pure Water Reverse Osmosis (RO) water treatment system. Water quality concerns ar

Seite 10 - Troubleshooting

3Operating Temperatures Maximum 100°F (37.8°C) Minimum 40°F (4.4°C)Operating PressureMaximum 85psi (6.0 kg/cm2)Minimum 40psi (2.80 kg/cm2)pH Paramet

Seite 11 - ITEM # EDP # DESCRIPTION

4STEP 2Step A – Remove nut (Item 11) and blue tubing (Item 12) from faucet. (Leave the nut and plastic delrin sleeve (Item 10) on the blue tube).Step

Seite 12 - Arsenic Facts

5Adapt-A-Valve™ InstallationVerify contents prior to installation:( 1 ) - Plastic Adapt-a-Valve™ & Black Collet ( 1 ) - Brass Adapter no washer (

Seite 13 - Service Record

6Drill hole and Connect 3⁄8" Black Tube from Faucet to the Drain SaddleIMPORTANT: The black 3⁄8" drain tube must be as SHORT and STRAIGHT

Seite 14

7 Start Up Instructions Step A– Turn on the incoming cold water at the angle stop valve. Turn the knob on the Adapt-A-Valve™ by turning coun-terclock

Seite 15

8Step E – Clean the filter housings (bowls) with a mild soap solution and rinse with water. Check O-rings and lubricate with water soluble lubricant.

Seite 16

9 Membrane Replacement This reverse osmosis system contains a replaceable component (the RO membrane) which is critical to the efficiency of the system