Model 2750 DownowService Manual IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference
3210 Timer AssemblyPage 10For Service Assembly Numbers, See the Back of this Manual
3210 Timer AssemblyPage 11Item No. Quantity Part No. Description 1 ...1 ...13870-01 ...Housing Assemb
Control Drive AssemblyPage 12For Service Assembly Numbers, See the Back of this Manual
Control Drive AssemblyPage 13 Item No. Quantity Part No. Description 1 ...1 ...18697 ...Backplat
Page 14Control Valve with 1700 InjectorFor Service Assembly Numbers, See the Back of this Manual
Page 15Control Valve with 1700 InjectorItem No. Quantity Part No. Description 1 ...1 ...14749 ...
Page 161600 Series Brine System AssemblyItem No. Quantity Part No. Description 1 ...1 ...10328 ...
Page 171700 Series Brine System AssemblyItem No. Quantity Part No. Description 1 ...1 ...14792 ...
Page 181” Meter Assembly Item No. Quantity Part No. Description 1 ...1 ...14959 ...Body, Meter,
Page 192310 Safety Brine Valve Item No. Quantity Part No. Description 1 ...1 ...19645 ...Body, S
Job Specication Sheet ...
Page 20Service Valve Operator Item No. Quantity Part No. Description 1 ...1 ...11749 ...Guide, B
Page 21TroubleshootingProblem Cause Correction1. Water conditioner fails to regenerate.A. Electrical service to unit has been interruptedA. Assure pe
Page 22TroubleshootingProblem Cause Correction8. Softener fails to draw brine. A. Drain line ow control is plugged.A. Clean drain line ow control.B
Page 23Water Conditioner Flow Diagrams61500-2750 DF_REVA
Page 24Water Conditioner Flow Diagrams61500-2750 DF_REVA
Page 25Flow Data & Injector Draw Rates
Page 26System #4 Typical Tank Installation with Optional MeterSystem #5 Interlock - Typical Twin Tank Installation with Optional 2 Meter Interlock and
Page 27System #6 Twin Series Regeneration Installation with a Remote MeterSystem #7 - Twin Alternator Installation with a Remote Meter
Page 28System #4 Immediate & Delayed Valve Wiring19201_REVB
Page 29System #4 Remote Signal Start Valve Wiring13768_REVG
Page 3Job Specication SheetJob No. ___________________Model No. _________________Water Test ________________Capacity Per Unit ___________Mineral Tank
Page 30System #5 Duplex Valve Wiring40502-01_REVB40502-02_REVB
Page 31System #6 Duplex Valve Wiring13632-01_REVK13632-02_REVL
Page 32System #7 Duplex 24V/120V 3-Way Valve Wiring19138-01_REVD19138-02_REVD
Page 33System #7 Duplex 230V 3-Way Valve Wiring17727-01_REVD17727-02_REVD
Page 34Service Assemblies24 Hour Gear Assembly:19205... Gear Assy, 24 Hour, Silver, 5600, 12AMBrine Line Flow (BLFC):60011-XX ... Brin
Page 35Notes
P/N 42327 Rev. A 1/07
General Commercial Pre-Installation Check ListPage 4WATER PRESSURE: A minimum of 25 pounds of water pressure is required for regeneration valve to ope
3200 Timer Setting ProcedurePage 5How To Set Days On Which Water Conditioner Is To Regenerate:Rotate the skipper wheel until the number “1” is at the
3210 Timer SettingsPage 6Typical Programming ProcedureCalculate the gallon capacity of the system, subtract the necessary reserve requirement and set
3200 & 3210 Timer SeriesPage 7How To Set The Regeneration Cycle Program:The regeneration cycle program on your water condi-tioner has been factory
Page 8For Service Assembly Numbers, See the Back of this Manual3200 Timer Assembly
Page 93200 Timer Assembly 1 ...... 1 ...... 13870 ...... Housing, Timer, 3200 2 ...... 1 ...